which objective should you use to focus on the specimen on your slide using the course objective?

by Prof. Elroy West DVM 5 min read

Use ONLY the fine focus control when focusing the higher power objectives (20X, 40X, 100X) on a slide. The course focus control is too course for focusing with these objectives. Objectives are fragile and must not be rammed into slides.

Full Answer

How do you use the coarse focus on a slide?

If You Want To Change The Objective Lens Through Which You Are Viewing A Specimen What Must You Do?You must turn the revolving nosepiece. If you want to change the objective lens through which you are viewing a specimen, what must you do? The coarse adjustment knob.Sep 27, 2017How do you change the

Why do you put the objective on top of the slide?

Feb 27, 2021 · You can not initially find the specimen on 40X objective. What should you do next? Use the course focus and move the slide around to look for the specimen. Use the diaphragm to dim the light because it is very bright on the 40X objective Assume the specimen is to small to see on the 40X objective Go back to the 4X objective and start the process all over to find it on …

How to use a 4X objective on a microscope?

Using the focus ring on your ocular lens bring the letter ‘e’ into sharp focus for that eye. The letter ‘e’ should now be in sharp focus for both of your eyes. d. Now, practice increasing the magnification. • First, position the slide so that the area of the slide that you wish to examine in more detail is in the exact center of the ...

Why can’t I focus on the specimen?

Feb 27, 2021 · Use the course focus and move the slide around to look for the specimen. Use the diaphragm to dim the light because it is very bright on the 40X objective Assume the specimen. Question: You are given a microscope slide and told to find the specimen on the slide using the 40x objective. You can not initially find the specimen on 40X objective.

What objective lens should be used when you begin to focus a specimen?

When focusing on a slide, ALWAYS start with either the 4X or 10X objective. Once you have the object in focus, then switch to the next higher power objective. Re-focus on the image and then switch to the next highest power.Jan 2, 2022

Which microscope objectives can you use the coarse focus knob with?

the coarse focus knobs? A: Only use the fine focus with the 40X and 100X objectives; can use the coarse focus with the 4X and 10X objectives.

Can you use coarse focus with the 40X objective?

Bring the 40x objective into position and focus only using the “fine focus” knob. Remember: The 4x objective is the only time you will use the “coarse focus” knob.

For which objective can you use the coarse adjustment to focus the specimen?

The gearing mechanism of the adjustment produces a large vertical movement of the stage with only a partial revolution of the knob. Because of this, the coarse adjustment should only be used with low power (4X and 10X objectives) and never with the high power lenses (40X and 100X).

What does the focus knob do on a microscope?

This knob is used to move the objective lenses toward or away from the specimen (see also fine focus). When using a microscope at 400x magnification or above you would want to have both coarse focus and fine focus knobs in order to view a crisp and clearly focused image through your microscope.

What is coarse focus used for?

Focus (coarse), The coarse focus knob is used to bring the specimen into approximate or near focus. Focus (fine), Use the fine focus knob to sharpen the focus quality of the image after it has been brought into focus with the coarse focus knob.

When using 100X objective is it better to use coarse focus or fine focus?

The coarse adjustment knob is used ONLY with the low power (4X, 10X) objectives. When focusing under the 40X or 100X objective, ONLY use the fine adjustment, never the coarse adjustment.Dec 14, 2021

Which focusing knob should you use with 10X and 40x objectives?

the Fine Focus KnobUse the Fine Focus Knob to bring the image into focus. When using 10x and 40x objectives, use ONLY the fine focus knob so that you don't scratch a lens or break a slide.

Which focus adjustment knob should you always use to focus the oil immersion lens?

Once the oil immersion (100X) objective lens is in position over the specimen, focus using only the fine adjustment knob. It should take no more than two turns in either direction to bring the specimen into sharp focus.

Which objective will be the only time you can use the coarse adjustment knob?

The coarse adjustment knob is used ONLY with the low power (4X, 10X) objectives. When focusing under the 40X or 100X objective, ONLY use the fine adjustment, never the coarse adjustment.

When focusing a specimen you should always start with what part of a microscope?

Start by rotating the objective lens to lowest power. Place a slide on the stage, label side up, with the coverslip centered. On LOW POWER ONLY, use the coarse focus knob to get the object into focus. If you cannot see anything, move the slide slightly while viewing and focusing.

Which objective lens should be in place when storing the microscope?

Always place the 4X objective over the stage and be sure the stage is at its lowest position before putting the microscope away. 9. Always turn off the light before putting the microscope away. 10.

What happens if you focus high power objectives with the coarse focus knob?

If you focus the high power objectives with the coarse focus knob, then you risk slamming the objective into the slide, risking the damage of both. Some high power objectives are spring-loaded, with a front-part that retracts when touched by the slide. This is a protective mechanism.

Why is 4x objective better than 4x objective?

The 4x objective also allows you to center the slide better, because it gives you a better overview. The 4x also has the greatest depth of field and this means that the whole specimen (top and bottom parts) are in focus. If you start with a high power objective and then start focusing, then you don’t know if you are focusing at the actual specimen or on the dust which is on the top of the cover glass.

What happens if you look at a specimen under high power?

If you look at a specimen under high power and then directly exchange the slide, you run the risk of losing focus again . The thickness of the mounting medium is not always the same and also the position of the specimen in the mounting medium can be different. Using the coarse (and even the fine focus) will take longer than starting again with the 4x objective and the coarse focus.